ELAU PacDrive Max4 Controller

ELAU PacDrive Max4 Controller

The PacDrive Max4 Controller is one of the oldest controller solutions from ELAU PacDrive product range.  The ELAU Max4 controller comes in 2 different versions: one which can control up to 8 MC4 drives, the other can control up to a maximum of 99 ELAU MC4 drives.  It uses real-time operating system VxWorks where VxWorks is responsible for logic and motion functions for a production or packaging machine. A PacDrive Controller synchronises, co-ordinates and generates the positioning functions for up to 8 servo drives which are connected via the SERCOS bus interface.

Several standardised field bus interfaces are available: PROFIBUS DP, CAN, CAN‐ open or DeviceNet. A variety of standard HMI systems, ranging from low-cost text displays to industrial PCs, can be used for the HMI functions.

Product ID code
– MAx-4 up to 8 axes:    MAx-4 / 11 / 02 / 016 / 08 / x / x / xx
– MAx-4 up to 99 axes:    MAx-4 / 11 / 02 / 016 / 99 / x / x / xx

Order code
– MAx-4 up to 8 axes:    13 13 02 51 – xxx
– MAx-4 up to 99 axes:    13 13 02 55 – xxx

 

ParameterValue
Product ID code
– MAx-4 up to 8 axes
– MAx-4 up to 99 axes
MAx-4 / 11 / 02 / 016 / 08 / x / x / xx
MAx-4 / 11 / 02 / 016 / 99 / x / x / xx
Order code
– MAx-4 up to 8 axes
– MAx-4 up to 99 axes
13 13 02 51 – xxx
13 13 02 55 – xxx
CPUIntel Pentium II 266 MHz
RAM32 MB
L2 Cache512 kB
NVRAM32 kB
CompactFlashTM Disk16 MB (internal)
Real time clock (RTC)yes, optional hardware required
Watchdogyes
Diagnosticsstatus LEDs
Real-time operating systemVxWorks
Programming languages
IEC 61131-3
Continuous Function Chart (CFC)
Function Block Diagram (FBD)
Instruction List (IL)
Ladder Diagram (LD)
Sequential Function Chart (SFC)
Structured Text (ST)
Communication interfaces
COM1
COM2
RS232 (X5)
RS485 (X6)
Network interfaceEthernet (10 Base-T) (X10)
Fieldbus interfacesPROFIBUS DP Master (12 MBaud) 1)
PROFIBUS DP Slave (12 MBaud) 1)
CAN (2.0B) 1)
CANopen 1)
DeviceNet Slave 1)
Ethernet/IP Slave 1)
1) optional hardware module required
Motion bus interfaceSERCOS interface (4 MBaud) (X7, X8)
PacNet interface1 PacNet interface1)
1) optional hardware module required
Encoder interface1 SinCos encoders
up to 10 incremental encoder1)
1) optional hardware module required
HMI interfaceOperator panels: RS485 using Modbus or
PROFIBUS DP
HMI software tools: OPC server (Windows
NT/2000/XP or Windows CE)
Remote Diagnostics interfaceWeb server or modem
Communication protocolshttp, ftp, SMTP (email)
Integrated trace recorder
(software oscilloscope)
8 channels
1 msec resolution
Integrated logger for
diagnostic messages
27 kB
Motion performance11 Servo axes @ 1 ms SERCOS cycle
23 Servo axes @ 2 ms SERCOS cycle
45 Servo axes @ 4 ms SERCOS cycle
max. 255 cam profiles running in parallel
PLC performance15 µsec for 1000 Bit instructions
unlimited number of PLC tasks
PLC task types: continuous, periodic or
event-triggered
Cycle time Fast Task: 250 µsec
Nominal I/O response time: 500 µsec
(reading input, processing data, setting out
put)
Programmable limit switches
(PLS)
max. 256
Type: dynamic
Outputs: memory or digital outputs
Inputs: external master encoder, virtual mas
ter encoder, or axes position
Scan time: 250 µsec
ParameterValue
Integrated digital inputs (X3)number: 20
range UIN 0 state: DC 0 … 6 V
range UIN 1 state: DC 20 … 33 V
input current: IIN = 5 mA on UIN = 24 V
pole safe: yes
input filter: 3.5 … 5.5 ms
Integrated analog inputs (X2)number: 2
range UIN: -7 … 10 V (impedance 100 k)
or
range IIN: 0 … 20 mA (impedance 500 R)
Integrated interrupt inputs (X4)number: 4
range UIN 0 state: DC 0 … 6 V
range UIN 1 state: DC 20 … 33 V
input current: IIN = 5 mA on UIN = 24 V
pole safe: yes
input filter: 0.07 … 0.17 ms
Integrated touchprobe inputs (X4)number: 16
range UIN 0 state: DC 0 … 6 V
range UIN 1 state: DC 20 … 33 V
input current: IIN = 5 mA on UIN = 24 V
pole safe: yes
input filter TP0 to TP15: 100 µs
resolution time TP0 to TP3:
15.6 µs @ 1, 2, 4 ms cycle time
resolution time TP4 to TP15:
15.6 µs @ 1 ms cycle time
32.25 µs @ 2ms cycle time
62.5 µs @ 4ms cycle time
Integrated digital outputs (X4)number: 16
output voltage: (+UL-3 V) < UOUT < +UL
rated current: I
e = 100 mA per output
switch current: I
emax < 0.5 A for 1 s
leakage current 0 signal: < 0.4 mA
transmission time: 0.04 … 0.31 ms
short-circuit-proof: yes
relay outputs: DC 20 … 30 V / 2 A
Integrated analog outputsnone
Additional digital and analog I/Osvia fieldbus
max. 3.584 Bytes digital/analog inputs and
max. 3.584 Bytes digital/analog outputs
max. number of stations: 126 (PROFIBUS)
ParameterValue
Additional fast digital I/Osvia PacNet
max. 128 inputs and 128 outputs
Additional touchprobe inputsvia PacNet
max. 16 touchprobe inputs
Power supplyDC 24 V (-15% / +25%) / max. 3.15 A
Power consumptionmax. 60 W
Uninterruptable power supply
UPS
external
Product size
Box size
width: 69 mm
height: 270 mm
depth: 240 mm
width: 100 mm
height: 400 mm
depth: 300 mm
Product weight
Boxed weight
2.4 kg
3.0 kg
Ambient conditions
– protection class
– ambient temp.
– insulation
– rel. humidity
IP20
+5 … +55 °C (in operation)
-25 … +70 °C (for storage and transport)
degree of pollution 2 …, no dewing allowed
5% … 85% climatic category 3K3 EN 60 721
ApprovalsCE, UL , cUL
ParameterValue
Scroll to Top