ELAU PacDrive MC-4 / 22 A

ELAU PacDrive MC-4 / 22 A

Product name: MC-4 / 11 / 22 / 400 V
Order number: 13 13 02 54
Rated connection voltage:  3 AC 380 V (-10%) to 480 V (+10%)
Mains frequency: 48 … 62 Hz
Control voltage/current: DC 24 V (-15% / +25%) / 1 A
DC-circuit voltage: DC 530 V to 680 V
rated power 8 kHz: 22.0 Aeff
peak current 1 s: 55 Aeff
rated power: 15.2 kVA
Approvals CE, UL, cUL

Category

Parameters

Value

Product configuration

Item name

MC-4 / 11 / 22 / 400 V

Order number

13 13 02 54

Power supply

Rated supply voltage

Min. 3 380  Vac (-10 %)

Max. 3 480  Vac (+10 %)

Supply frequency (INC)

48 … 62 Hz

Control voltage / -current (ISC)

24 Vdc (-15 % / +25 %) / 1 A

DC circuit

DC_Bus Voltage

530 Vdc … 680  Vdc

Capacity

705 µF

≥Bleeder  ON

820 Vdc

≥Bleeder  OFF

800 Vdc

Overvoltage

860 Vdc

Bleeder resistor

42 ohm

Bleeder-continuous power

150 W

Bleeder-peak power

15 kW

Motor connection

Rated current 8 kHz

22 Aeff

Peak current 1 s

55 Aeff

Rated output

15.2 kVA

Stray power

Electronics power supply

approx. 12 W

Bleeder (internal)

0 … 150 W (depending on the application)

Power unit

approx. 15 W / A

Inputs

Input voltage / -current

20 … 30  Vdc / 5 mA

ie-input

20 … 30 Vdc / 30 mA

Input filter

[5 ms]

Outputs

Relay-outputs

20 … 30  Vdc / 2 A

Dimensions

Dimensions packaging

DxWxH (mm) / (in.): 310x160x400 / 12.2×6.3×15.7

Weight

Weight (with packaging)

6.3 kg (7.0 kg) / 13.9 lbs (15.4  lbs)

Ventilation

Fan

internal, temperature-controlled, (switching on threshold

= 55 °C / 131  °F)

Overvoltage category

 

K III, ≤2 (DIN VDE 0110)

Overvoltage protection

 

Class 1 (DIN VDE 0160)

Radio interference level

 

Class A EN 55011 / EN 61800 – 3

Scroll to Top